Review results from Cooling Analysis Strategies unit on dustpan and determine possible changes to minimize temperature difference between cavity and core
Possible changes include
Water line layout
Adding circuits/branches
Changing position
Changing circuit temperatures
Up to 3 different temperatures allowed
Adding inserts
Changing flow rates